| Fiber Type |
OS2 |
| Fiber Grade (Acc. to ITU-T) |
G.652D & G.657A1 |
| Fiber Count |
12 |
| Fiber Color Coding |
TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua |
| Subunit Waterblocking |
Gel Filled |
| Subunit Diameter |
3.3 mm |
| Subunit Color |
TIA coding (Gxxxxxx.T): Natural |
| Cable Core Water Blocking |
Waterblocking Glass Yarns + Tape |
| Armor Type and Material |
CST - Corrugated Steel Tape |
| Jacket Material |
LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Nominal Diameter |
9.0 mm (0.35 in) |
| Optical Characteristics |
| Wavelength |
1310 nm / 1550 nm / 1625 nm |
| Max. Attenuation |
0.39 dB/km / 0.24 dB/km / 0.29 dB/km |
| Mechanical Tests |
| Min. Bend Radius (Installation) |
180 mm (IEC 60794-1-21-E6) |
| Min. Bend Radius (Operation) |
180 mm (IEC 60794-1-21-E11) |
| Max. Tensile Strength (Installation) |
2400 N (IEC 60794-1-21-E1) |
| Max. Tensile Strength (Operation) |
800 N (IEC 60794-1-21-E1) |
| Max. Crush Resistance (Installation) |
22 kN/m (IEC 60794-1-21-E3) |
| Max. Crush Resistance (Operation) |
11 kN/m (IEC 60794-1-21-E3) |
| Bulk Cable Weight |
104 kg/km (69.9 lbs/1000 ft) |
| Installation Temperature Range |
-5 C to +50 C |
| Operating Temperature Range |
-30 C to +55 C |
| Storage Temperature Range |
-30 C to +55 C |
| Environmental Suitability |
Indoor/Outdoor - Euroclass Dca |
| Flammability / Reaction to Fire |
IEC 60332-1-2, IEC 60332-3-25 |
| Resistance to Fire |
IEC 60331-25-E120 / EN 50200-PH120 ANNEX E |
| CPR Compliance |
Euroclass: Dca-s1,d1,a1; UKCA Class: Dca-s1,d1,a1 |
| ISO/IEC Compliance |
IEC 60794, ISO/IEC 11801-1 |
| European Halogen Free Standards |
IEC 60754-1 & 60754-2; IEC 61034-2 |
| UK Regulation Compliance |
UKCA Mark |