Cisco C9500-48Y4C-EDU
SpecificationProduct Code C9500-48Y4C-EDU
Product Description Catalyst 9500 48-port x 1/10/25G and 4-port 40/100G , EDU
Dimensions (H x W x D) 1.73 x 17.5 x 18.0 in
Rack units (RU) 1 RU
Minimum software requirement Cisco IOS XE Software Release 16.8.1a
ASIC UADP 3.0
Switching capacity Up to 3.2 Tbps
Forwarding rate Up to 1 Bpps
Total number of MAC addresses Up to 82,000
Total number of IPv4 routes (Address Resolution Protocol [ARP] plus learned routes) Up to 212,000 indirect + directUp to 90,000 host/ARP
Total number of IPv6 routes Up to 212,000 indirect + directUp to 90,000 host
Total number of IPv4 Multicast routes Up to 32,000
Total number of IPv6 Multicast routes Up to 32,000
QoS ACL scale Up to 16000
Security ACL scale Up to 27000FNF
entries Up to 98,000
DRAM 16 GB
Flash 16 GB
VLAN IDs 4094
Total Switched Virtual Interfaces (SVIs) 4000
Jumbo frame 9216 bytes
Safety certifications- C9500-12Q, C9500-24Q, C9500-40X, C9500-16X
- UL 60950-1
- CAN/CSA-C22.2 No. 60950-1
- EN 60950-1
- IEC 60950-1
- AS/NZS 60950-1
- GB4943
- C9500-32C, C9500-32QC, C9500-24Y4C, C9500-48Y4C
- IEC 60950-1 plus Am1, Am2 Am9, Am10, Am11, Am12 and all deviations and differences
- AS/NZS 60950.1.2011
- CAN/CSA-C22.2 No. 60950-1-07
- GB 4943-95
- EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences
- NOM-019-SCFI-1998
- UL 60950-1, Second Edition
EMI and EMC compliance - 47 CFR Part 15 Class A
- CNS13438: 2006 Class A
- EN 300 386 V1.6.1
- EN61000-3-2: 2014
- EN61000-3-3: 2013
- ICES-003 Issue 6: 2016 Class A
- KN 32: 2015 Class A
- TCVN 7189: 2009 Class A
- EN 55032:2012/ AC:2013 Class A
- EN 55032:2015 Class A
- CISPR 32 Edition 2 Class A
- V-2/2015.04 Class A
- V-3/2015.04 Class A
- CISPR24: 2010 + A1: 2015
- EN 300 386 V1.6.1
- EN55024: 2010 + A1: 2015
- KN35: 2015
- TCVN 7317: 2003
Input voltage 90 to 264 VAC
Operating temperature 32to 104F (0to 40C)
Storage temperature -4to 149F (-20to 65C)
Relative humidity operating and nonoperating noncondensingAmbient (noncondensing) operating: 5% to 90%Ambient (noncondensing) nonoperating and storage: 5% to 95%
NEBS criteria levelsNEBS:
- Normal operating temperature range: 5C to 40C (up to 1829 meters (6000 ft)
- Short term operating temperature range: -5C to 55C
- Normal Relative Humidity range: 5% to 85%
- Short term Relative Humidity range: 5% to 93%
- Operating Altitude: up to 1829 m (6000 ft) at 55C
- ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.
- SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue
Altitude Operation up to 13,000 feet at 40C
MTBF (hours) 316,960
Tags:
Cisco C9500-48Y4C-EDU Price Dubai Cisco C9500-48Y4C-EDU Supplier Dubai Cisco C9500-48Y4C-EDU Sale Dubai Cisco C9500-48Y4C-EDU Features Dubai Cisco IT Products Dubai Cisco IT Supplies Dubai